Equipment Schedules

Pre-Defined Equipment Schedules in BAS Systems

Enertec-BAS Corporation provides a comprehensive set of pre-defined Equipment Schedules included in all BAS systems. Each schedule contains a detailed sequence of operations and a wiring schematic, configured to support a wide range of HVAC and building control equipment. 

  • #1 Heat Pump, Single Zone or VariZone® Server, 1 Compressor, Backup Heat, No Economizer, RV Cooling 
  • #2 Heat Pump, Single Zone or VariZone® Server, 1 Compressor, Backup Heat, No Economizer, RV Heating 
  • #3 Heat Pump, Single Zone or VariZone® Server, 1 Compressor, Backup Heat, No Economizer, RV Cooling, 2 Units 
  • #4 Heat Pump, Single Zone or VariZone® Server, 1 Compressor, Backup Heat, No Economizer, RV Heating, 2 Units 
  • #5 Heat Pump, Single Zone or VariZone® Server, 1 Compressor, Backup Heat, Economizer (Staged or Analog), RV Cooling 
  • #6 Heat Pump, Single Zone or VariZone® Server, 1 Compressor, Backup Heat, Economizer (Staged or Analog), RV Heating 
  • #7 Heat Pump, Single Zone or VariZone® Server, 2 Compressors, Backup Heat, Economizer (Staged or Analog), RV Cooling 
  • #8 Heat Pump, Single Zone or VariZone® Server, 2 Compressors, Backup Heat, Economizer (Staged or Analog), RV Heating 
  • #9 Air Conditioner, Single Zone or VariZone® Server, 1 Compressor, Heat, No Economizer 
  • #10 Air Conditioner, Single Zone or VariZone® Server, 1 Compressor, Heat, No Economizer, 2 Units 
  • #11 Air Conditioner, Single Zone or VariZone® Server, 1 Compressor, Heat, Economizer (Staged or Analog) 
  • #12 Air Conditioner, Single Zone or VariZone® Server, 2 Stages Cooling, 2 Stages Heat, Economizer (Staged or Analog) 
  • #13 VAV Damper, Cooling Only, 3-Point Floating or Analog Actuator 
  • #14 VAV Damper, Cooling Only, 3-Point Floating or Analog Actuator, 4 Zones 
  • #15 VAV Box, Fan, Cooling, Electric Heat, 3-Point Floating or Analog Actuator, Constant Air Volume 
  • #16 VAV Box, Fan, Cooling, Electric Heat, 3-Point Floating or Analog Actuator, Constant Air Volume, 2 Zones 
  • #17 VAV Box, Fan, Cooling, Electric Heat, 3-Point Floating or Analog Actuator, Variable Air Volume 
  • #18 VAV Box, Fan, Cooling, Electric Heat, 3-Point Floating or Analog Actuator, Variable Air Volume, 2 Zones 
  • #19 VAV Box, Fan, Cooling, Hydronic Heat, 3-Point Floating or Analog Actuators, Constant Air Volume 
  • #20 VAV Box, Fan, Cooling, Hydronic Heat, 3-Point Floating or Analog Actuators, Variable Air Volume 
  • #21 Fan Coil, Heating, 4 Units 
  • #22 Fan Coil, Cooling, 4 Units 
  • #23 Unit Ventilator, Electric Heat, Economizer (Staged or Analog) 
  • #24 Unit Ventilator, Electric Heat, Economizer (Staged or Analog), 2 Units 
  • #25 Unit Ventilator, Electric Heat, Modulating Economizer, 3-Point Floating or Analog Actuator 
  • #26 Unit Ventilator, Electric Heat, Modulating Economizer, 3-Point Floating or Analog Actuator, 2 Units 
  • #27 Unit Ventilator, Hydronic Heat, 3-Point Floating or Analog Actuator, Economizer 
  • #28 Unit Ventilator, Hydronic Heat, Modulating Economizer, 3-Point Floating or Analog Actuators 
  • #29 Air Handling Unit, 4 Stage Heat, Outdoor Reset 
  • #30 Air Handling Unit, 3-Way Mixing Valve, 3-Point Floating or Analog Actuator, Outdoor Reset 
  • #31 Air Handling Unit, 3 Stage Heat, Modulating Cooling, Modulating Economizer, Analog Actuators, 2 Units 
  • #32 Hydronic Heat Pump Loop Control, 1 Stage Heat, 4 Stage Cooling, 2 Loop Pumps 
  • #33 Chiller, 4 Stage Cooling, 2 Chilled Water Pumps 
  • #35 Boiler, 4 Stage Heat, Outdoor Reset 
  • #36 Boiler, 3-Way Mixing Valve, 3-Point Floating or Analog Actuator, Outdoor Reset 
  • #40 Air Handling Unit, 4 Stage Cooling, 1 Stage Heat, Analog Cooling, 3-Point or Analog Economizer, Single Zone or VAV Server 
  • #41 Air Handling Unit, Modulating Duct Static Pressure Control, Single Zone or VAV Server, 2 Units 
  • #42 Air Handling Unit, Modulating Building Static Pressure Control, 2 Units 
  • #50 VariZone® Damper, 3-Point Floating or Analog Actuator 
  • #51 VariZone® Damper, 3-Point Floating or Analog Actuator, 4 Zones 
  • #52 VariZone® Box, Fan Powered, Electric Backup Heat, 3-Point Floating or Analog Actuator, Constant Air Volume 
  • #53 VariZone® Box, Fan Powered, Electric Backup Heat, 3-Point Floating or Analog Actuator, Constant Air Volume, 2 Zones 
  • #54 VariZone® Box, Fan Powered, Electric Backup Heat, 3-Point Floating or Analog Actuator, Variable Air Volume 
  • #55 VariZone® Box, Fan Powered, Electric Backup Heat, 3-Point Floating or Analog Actuator, Variable Air Volume, 2 Zones 
  • #56 VariZone® Box, Fan Powered, Hydronic Backup Heat, 3-Point Floating or Analog Actuators, Constant Air Volume 
  • #57 VariZone® Box, Fan Powered, Hydronic Backup Heat, 3-Point Floating or Analog Actuators, Variable Air Volume 
  • #60 VAV Dampers, Dual Duct System, 3-Point Floating or Analog Actuators, 2 Zones 
  • #63 Lighting Control, 8 Zones 
  • #64 Reserved for Custom Output Definition 
  • #34, #37-#39, #43-#49, #58-#59, #61-#62 – These numbers are currently not assigned to any Equipment Schedule. 

Each of these Equipment Schedules is included by default with every BAS system, providing users with ready-made control sequences and wiring diagrams to simplify installation, configuration, and operation across diverse HVAC and building automation applications.