List of Equipment Schedules The following Equipment Schedules are pre-defined and included in all BAS systems. Each Equipment Schedule includes a sequence of operations and wiring schematic. #1- Heat Pump, Single Zone or VariZoneÒ#2- Heat Pump, Single Zone or VariZoneÒ Server, 1 Compressor, Backup Heat, No Economizer, RV Heating #3- Heat Pump, Single Zone or VariZoneÒ Server, 1 Compressor, Backup Heat, No Economizer, RV Cooling, 2 Units #4- Heat Pump, Single Zone or VariZoneÒ Server, 1 Compressor, Backup Heat, No Economizer, RV Heating, 2 Units #5- Heat Pump, Single Zone or VariZoneÒ Server, 1 Compressor, Backup Heat, Economizer (Stg or Anl), RV Cooling #6- Heat Pump, Single Zone or VariZoneÒ Server, 1 Compressor, Backup Heat, Economizer (Stg or Anl), RV Heating #7- Heat Pump, Single Zone or VariZoneÒ Server, 2 Compressors, Backup Heat, Economizer (Stg or Anl), RV Cooling #8- Heat Pump, Single Zone or VariZoneÒ Server, 2 Compressors, Backup Heat, Economizer (Stg or Anl), RV Heating #9- Air Conditioner, Single Zone or VariZoneÒ Server, 1 Compressor, Heat, No Economizer #10- Air Conditioner, Single Zone or VariZoneÒ Server, 1 Compressor, Heat, No Economizer, 2 Units #11- Air Conditioner, Single Zone or VariZoneÒ Server, 1 Compressor, Heat, Economizer (Stg or Anl) #12- Air Conditioner, Single Zone or VariZoneÒ Server, 2 Stages Cooling, 2 Stages Heat, Economizer (Stg or Anl #13- VAV Damper, Cooling Only, 3 Point Floating or Analog Actuator #14- VAV Damper, Cooling Only, 3 Point Floating or Analog Actuator, 4 Zones #15- VAV Box, Fan, Cooling, Electric Heat, 3 Point Floating or Analog Actuator, Constant Air Volume #16- VAV Box, Fan, Cooling, Electric Heat, 3 Point Floating or Analog Actuator, Constant Air Volume, 2 Zones #17- VAV Box, Fan, Cooling, Electric Heat, 3 Point Floating or Analog Actuator, Variable Air Volume #18- VAV Box, Fan, Cooling, Electric Heat, 3 Point Floating or Analog Actuator, Variable Air Volume, 2 Zones #19- VAV Box, Fan, Cooling, Hydronic Heat, 3 Point Floating or Analog Actuators, Constant Air Volume #20- VAV Box, Fan, Cooling, Hydronic Heat, 3 Point Floating or Analog Actuators, Variable Air Volume #21- Fan Coil, Heating, 4 Units #22- Fan Coil, Cooling, 4 Units #23- Unit Ventilator, Electric Heat, Economizer (Stg or Anl) #24- Unit Ventilator, Electric Heat, Economizer (Stg or Anl), 2 Units #25- Unit Ventilator, Electric Heat, Modulating Economizer, 3 Point Floating or Analog Actuator #26- Unit Ventilator, Electric Heat, Modulating Economizer, 3 Point Floating or Analog Actuator, 2 Units #27- Unit Ventilator, Hydronic Heat, 3 Point Floating or Analog Actuator, Economizer #28- Unit Ventilator, Hydronic Heat, Modulating Economizer, 3 Point Floating or Analog Actuators #29- Air Handling Unit, 4 Stage Heat, Outdoor Reset #30- Air Handling Unit, 3 Way Mixing Valve, 3 Point Floating or Analog Actuator, Outdoor Reset #31- Air Handling Unit, 3 Stage Heat, Modulating Cooling, Modulating Economizer, Analog Actuators, 2 Units #32- Hydronic Heat Pump Loop Control, 1 Stage Heat, 4 Stage Cooling, 2 Loop Pumps #33- Chiller, 4 Stage Cooling, 2 Chill Water Pumps #34- Not Currently Used #35- Boiler, 4 Stage Heat, Outdoor Reset #36- Boiler, 3 Way Mixing Valve, 3 Point Floating or Analog Actuator, Outdoor Reset #37-39 Not Currently Used #40- Air Handling Unit, 4 Stg Cool, 1 Stg Heat, Analog Cool, 3 Pt or Analog Economizer, Single Zone or VAV Server #41- Air Handling Unit, Modulating Duct Static Pressure Control, Single Zone or VAV Server, 2 Units #42- Air Handling Unit, Modulating Building Static Pressure Control, 2 Units #43-49 Not Currently Used #50- VariZoneÒ Damper, 3 Point Floating or Analog Actuator #51- VariZoneÒ Damper, 3 Point Floating or Analog Actuator, 4 Zones #52- VariZoneÒ Box, Fan Powered, Electric B/U Heat, 3 Point Floating or Analog Actuator, Constant Air Volume #53- VariZoneÒ Box, Fan Powered, Electric B/U Heat, 3 Point Floating or Analog Actuator, Constant Air Volume, 2 Zones #54- VariZoneÒ Box, Fan Powered, Electric B/U Heat, 3 Point Floating or Analog Actuator, Variable Air Volume #55- VariZoneÒ Box, Fan Powered, Electric B/U Heat, 3 Point Floating or Analog Actuator, Variable Air Volume, 2 Zones #56- VariZoneÒ Box, Fan Powered, Hydronic B/U Heat, 3 Point Floating or Analog Actuators, Constant Air Volume #57- VariZoneÒ Box, Fan Powered, Hydronic B/U Heat, 3 Point Floating or Analog Actuators, Variable Air Volume #58-59 Not Currently Used #60- VAV Dampers, Dual Duct System, 3 Point Floating or Analog Actuators, 2 Zones #61-62 Not Currently Used #63- Lighting Control, 8 Zones #64- Reserved for Custom Output Definition
| |
© 1988-2014 Enertec-BAS Corporation All rights reserved. |