List of Equipment Schedules

The following Equipment Schedules are pre-defined and included in all BAS systems. Each Equipment Schedule includes a sequence of operations and wiring schematic.

#1- Heat Pump, Single Zone or VariZoneÒ Server, 1 Compressor, Backup Heat, No Economizer, RV Cooling
#2- Heat Pump, Single Zone or
VariZoneÒ Server, 1 Compressor, Backup Heat, No Economizer, RV Heating
#3- Heat Pump, Single Zone or
VariZoneÒ Server, 1 Compressor, Backup Heat, No Economizer, RV Cooling, 2 Units
#4- Heat Pump, Single Zone or
VariZoneÒ Server, 1 Compressor, Backup Heat, No Economizer, RV Heating, 2 Units
#5- Heat Pump, Single Zone or
VariZoneÒ Server, 1 Compressor, Backup Heat, Economizer (Stg or Anl), RV Cooling
#6- Heat Pump, Single Zone or
VariZoneÒ Server, 1 Compressor, Backup Heat, Economizer (Stg or Anl), RV Heating
#7- Heat Pump, Single Zone or
VariZoneÒ Server, 2 Compressors, Backup Heat, Economizer (Stg or Anl), RV Cooling
#8- Heat Pump, Single Zone or
VariZoneÒ Server, 2 Compressors, Backup Heat, Economizer (Stg or Anl), RV Heating
#9- Air Conditioner, Single Zone or
VariZoneÒ Server, 1 Compressor, Heat, No Economizer
#10- Air Conditioner, Single Zone or
VariZoneÒ Server, 1 Compressor, Heat, No Economizer, 2 Units
#11- Air Conditioner, Single Zone or
VariZoneÒ Server, 1 Compressor, Heat, Economizer (Stg or Anl)
#12- Air Conditioner, Single Zone or
VariZoneÒ Server, 2 Stages Cooling, 2 Stages Heat, Economizer (Stg or Anl
#13- VAV Damper, Cooling Only, 3 Point Floating or Analog Actuator
#14- VAV Damper, Cooling Only, 3 Point Floating or Analog Actuator, 4 Zones
#15- VAV Box, Fan, Cooling, Electric Heat, 3 Point Floating or Analog Actuator, Constant Air Volume
#16- VAV Box, Fan, Cooling, Electric Heat, 3 Point Floating or Analog Actuator, Constant Air Volume, 2 Zones
#17- VAV Box, Fan, Cooling, Electric Heat, 3 Point Floating or Analog Actuator, Variable Air Volume
#18- VAV Box, Fan, Cooling, Electric Heat, 3 Point Floating or Analog Actuator, Variable Air Volume, 2 Zones
#19- VAV Box, Fan, Cooling, Hydronic Heat, 3 Point Floating or Analog Actuators, Constant Air Volume
#20- VAV Box, Fan, Cooling, Hydronic Heat, 3 Point Floating or Analog Actuators, Variable Air Volume
#21- Fan Coil, Heating, 4 Units
#22- Fan Coil, Cooling, 4 Units
#23- Unit Ventilator, Electric Heat, Economizer (Stg or Anl)
#24- Unit Ventilator, Electric Heat, Economizer (Stg or Anl), 2 Units
#25- Unit Ventilator, Electric Heat, Modulating Economizer, 3 Point Floating or Analog Actuator
#26- Unit Ventilator, Electric Heat, Modulating Economizer, 3 Point Floating or Analog Actuator, 2 Units
#27- Unit Ventilator, Hydronic Heat, 3 Point Floating or Analog Actuator, Economizer
#28- Unit Ventilator, Hydronic Heat, Modulating Economizer, 3 Point Floating or Analog Actuators
#29- Air Handling Unit, 4 Stage Heat, Outdoor Reset
#30- Air Handling Unit, 3 Way Mixing Valve, 3 Point Floating or Analog Actuator, Outdoor Reset
#31- Air Handling Unit, 3 Stage Heat, Modulating Cooling, Modulating Economizer, Analog Actuators, 2 Units
#32- Hydronic Heat Pump Loop Control, 1 Stage Heat, 4 Stage Cooling, 2 Loop Pumps
#33- Chiller, 4 Stage Cooling, 2 Chill Water Pumps
#34- Not Currently Used
#35- Boiler, 4 Stage Heat, Outdoor Reset
#36- Boiler, 3 Way Mixing Valve, 3 Point Floating or Analog Actuator, Outdoor Reset
#37-39 Not Currently Used
#40- Air Handling Unit, 4 Stg Cool, 1 Stg Heat, Analog Cool, 3 Pt or Analog Economizer, Single Zone or VAV Server
#41- Air Handling Unit, Modulating Duct Static Pressure Control, Single Zone or VAV Server, 2 Units
#42- Air Handling Unit, Modulating Building Static Pressure Control, 2 Units
#43-49 Not Currently Used
#50-
VariZoneÒ Damper, 3 Point Floating or Analog Actuator
#51-
VariZoneÒ Damper, 3 Point Floating or Analog Actuator, 4 Zones
#52-
VariZoneÒ Box, Fan Powered, Electric B/U Heat, 3 Point Floating or Analog Actuator, Constant Air Volume
#53-
VariZoneÒ Box, Fan Powered, Electric B/U Heat, 3 Point Floating or Analog Actuator, Constant Air Volume, 2 Zones
#54-
VariZoneÒ Box, Fan Powered, Electric B/U Heat, 3 Point Floating or Analog Actuator, Variable Air Volume
#55-
VariZoneÒ Box, Fan Powered, Electric B/U Heat, 3 Point Floating or Analog Actuator, Variable Air Volume, 2 Zones
#56-
VariZoneÒ Box, Fan Powered, Hydronic B/U Heat, 3 Point Floating or Analog Actuators, Constant Air Volume
#57-
VariZoneÒ Box, Fan Powered, Hydronic B/U Heat, 3 Point Floating or Analog Actuators, Variable Air Volume
#58-59 Not Currently Used
#60- VAV Dampers, Dual Duct System, 3 Point Floating or Analog Actuators, 2 Zones
#61-62 Not Currently Used
#63- Lighting Control, 8 Zones
#64- Reserved for Custom Output Definition

 